About the installation position of the agitator

When installing on a square tank, the tank corner parts act as baffle plates, so in principle, agitator is mounted in the center, but in the case of a cylindrical tank, agitator should be mounted eccentrically or install in the tank with baffle plate.

* Never install an agitator in the center of a cylindrical tank.
If the impellers are too close to the tank wall by eccentric installation,the counter flow may affect the agitator and make the shaft vibrate.
If it is difficult to install an agitator in the proper position due to a manhole being in the center of top plate in a PE molded tank or others, please contact us for the mounting position.
* It is strictly prohibited for the liquid level to pass through the impeller position during operetion, or to operate without liquid.
Be sure to operate the agitator with the minimum liquid level secured. Please contact us if a pass through of liquid level or no load operation is necessary.