Tech & Tools
Technical information
- HOME
- Tech & Tools
- L/PAD type dissolver Selection of undiluted solution transfer pump
L/PAD type dissolver Selection of undiluted solution transfer pump
1. L/PAD-30 type Solution discharge rate:320(L/h)
2. Solution concentration:0.2%
3. Undiluted solution concentration:40%
4. Dilution rate = Undiluted solution / solution concentration = 200 times
∴Dilution water:Undiluted solution = 199:1
5. Required undiluted solution rate:Q = 320 / 199 ≒ 1.6(L/h)
6. Selection of undiluted transfer pump(Safety rate is 1.5 times):1.6×1.5 = 2.4(L/h)= 40(ml/min)
7. For the raw liquid transfer pump, select a model with a discharge volume of around 50 (ml/min).