Products
- HOME
- Products
- Water quality controller/sensor
- pH / ORP electrode (Chemipack type sensor)
pH / ORP electrode (Chemipack type sensor)
✔ Easy electrode replacement and maintenance
✔ KCL-enclosed chemi-pack type allows you to check the degree of KCL consumption at a glance
✔ 3 types of immersion type / distribution type / immersion type are available
Features
● Three types: immersion type / distribution type / immersion type.
● Easy electrode replacement and maintenance.
● KCl-encapsulated chemi-pack type allows you to check the degree of KCl consumption at a glance.
● High temperature specifications of 45 to 80 ° C are also available.
Corresponding instruments: NN-2000 / NN-1000 / NN-100 / NN-110 / NN-200 / NN-210
It can also be connected to the Prominent Dalkometer D1C.
specification
Model | pH | ORP | ||||
---|---|---|---|---|---|---|
Dipping type | Distribution type | Immersion type | Dipping type | Distribution type | Immersion type | |
TCLP | TCCP | TCPP | TCLM | TCCM | TCPM | |
Measurement range | 2~12pH | ±1000mV | ||||
Operating temperature | 0~60℃ | 0~45℃ | 0~60℃ | 0~45℃ | ||
Electrode model | TPH | TOR | ||||
Holder material | PP | PVC | PP | PVC | ||
Working pressure | 0~0.15MPa | – | 0~0.15MPa | – | ||
Standard accessories | pH 4/7 standard solution 1 bottle each | Kinhydron powder x 5 bags | ||||
option | Mounting bracket (immersion type), relay box, beaker set (200 ml x 3), dedicated cable (2 cores, 4 cores) |
* Holder material for high temperature (45-80 ℃): SUS304, 316, etc. can also be manufactured.
* This product is a single-use type with built-in KCl. It cannot be replenished.
Model
TC | ① | ② | – | ③ | ④ | – | ⑤ | ⑥ | – | ⑦ | – | ⑧ | ⑨ |
---|
①Holder type | L: Dipping type C: Distribution type P: Immersion type |
---|---|
②Measurement item | P: for pH M: for ORP |
③Immersion type holder length (No entry for distribution / implantation type) |
05: 500mm 10: 1000mm 15: 1500mm blank |
④Temperature compensation | Blank: None T: Yes (Pt100) |
⑤Presence or absence of mounting flange | Blank: None F: Yes (JIS10KF) LF: Loose flange (* Immersion type with flange only) |
⑥Flange caliber (Only for immersion type with flange and distribution type. JIS10 KF size) |
Blank: No flange 40-100: For immersion type (F) 50-65: For immersion type (LF) 25-80: For distribution type |
⑦Electrode lead wire length | Blank: Standard 6m 10:10m 20:20m 30:30m |
⑧Special specifications | Blank: None Z: Special specifications Z4: High temperature holder (SUS304) Z6: High temperature holder (SUS316) |
⑨Connection instrument specifications | Blank: For Tohkemy Instruments P: For Prominent Instruments (for D1Ca) P2: For Prominent Instruments (for D1Cb / c) |
Head Office
1-12-11 Tagawakita, Yodogawa-ku,Osaka
532-0021
Overseas Business Department
TEL +81-6-6301-6460
FAX +81-6-6308-3022