- Water quality controller/sensor
- 4 contacts (NN-2000)
4 contacts (NN-2000)
✔ Chemipack type pH / ORP electrode can be directly connected
✔ Easy operation, time division control and ON-OFF control are possible
✔ Equipped with 2 control contacts (H / L contacts) and upper / lower limit contacts (HH / LL contacts)
✔ External DC4 ~ 20 mA Display and control by analog signal input is possible
Features
● Either pH / ORP can be measured.
● Chemipack type pH / ORP electrodes can be directly connected.
● With pH temperature compensation function (Pt100)
● Display and control with an external DC4-20mA analog signal input is also possible.
● Automatic water quality control (time division proportional or ON-OFF control) is possible with simple operation.
● Equipped with 2 control contacts (H / L contacts) and upper / lower limit contacts (HH / LL contacts).
● DC4-20mA transmission output, with display / transmission output hold function.
Use
Continuous neutralization
The pH value of the continuously flowing raw water is adjusted to the neutral range and drained by overflow. Adjust the operating time of the grout pump to adjust the pH and inject the optimum amount of grout for the target value. If the pH value is high, the pH value may be adjusted in two steps.
Batch neutralization
If the amount to be discharged per day is fixed, the entire amount is once received in the tank, and the pH value is slowly and surely adjusted and discharged while circulating and stirring. Although it takes time to process, it can reliably process high pH values.
Carbon dioxide neutralization
Basically, it is the same idea as continuous neutralization, but when the pH value of raw water is about 8 to 11, it is a system that neutralizes using carbon dioxide gas for safer neutralization. Since high-pressure carbon dioxide injection requires finer control, it is controlled by using the NN2000 and PXR5 type PID controller together.
Redox treatment
If bacteria such as bacteria are present in the wastewater, sterilize (oxidize) with sodium hypochlorite (sterilizer), and when sterilization is completed, inject a reducing agent to offset (reduce) the sterilizing power. To do. The control is performed using an ORP (oxidation-reduction potential) meter.
specification
Model | NN-2000 | ||||
---|---|---|---|---|---|
Measurement input | pH:Glass electrode | ORP:Gold or platinum electrode | DC4-20mA | ||
Input resistance | 1012Ω以上 | 50Ω | |||
Measurement instruction range | 0.00~14.00/0.0~14.0pH or 2.00~12.00/2.0~12.0pH |
-1000~1000mV or -700~700mV |
pH | 0.00~14.00/0.0~14.0pH 2.00~12.00/2.0~12.0pH |
|
ORP | ±1000/±700mV | ||||
ppm | 0.00~2.00/0.0~2.0ppm | ||||
% | 0.0~100.0/0~100% | ||||
Minimum instruction unit | 0.01pH/0.1pH | 1mV | pH | 0.01pH/0.1pH | |
ORP | 1mV | ||||
ppm | 0.1ppm/1ppm | ||||
% | 0.1%/1% | ||||
Instruction accuracy | ±0.03pH ±1digit | ±10mV ±1digit | F.S.±0.5% ±1digit | ||
Compatible temperature compensation electrode | Pt100 | – | – | ||
Output contacts | ON-OFF control HH / LL: 1c each AC250V 3A (resistive load) Time division proportional or ON-OFF control H / L: 1a each AC250V 3A (resistive load) |
||||
Transmission output | DC4-20mA Insulated load resistance 500Ω | ||||
Power supply | AC100 / 110V or AC200 / 220V ± 10% 50 / 60Hz | ||||
power consumption | 10VA Less than | ||||
Ambient temperature / humidity | 0~50℃ 85% Less than | ||||
mass | about 1.25kg |