- Odor reduction by use of chlorine dioxide [Bello Zon]
Odor reduction by use of chlorine dioxide [Bello Zon]
- User
- Seafood product industry in the Shikoku region (Japan)
- Product used
-
Verozon CDK series (ClO2 generation: 8-12,000g / h)
Verozon CDL series (ClO2 generation: 0-120g / h)
Verozon CDV series (ClO2 generation amount: 1-2,000g / h) - Overview
- Equipment that uses chlorine dioxide to suppress the odor that is a problem in fish processing factories. It is much more effective than sodium hypochlorite.
- Category
- Unit Systems
Issues / requests
We want to reduce the impact of the odor generated in the recycling process on the environment inside the factory _and the surrounding environment. I want to efficiently reduce odor while using the existing deodorizing scrubber tower. Wastewater treatment equipment Due to the large capacity, it is difficult to use a large amount of water.
Tohkemy's proposal
The cause of the odor is "trimethylamine", which is produced by decomposing dimethylamine derived from fish. Test introduction of a device that injects "chlorine dioxide water", which is an effective disinfectant, while generating it locally. In addition, a pH control device for circulating water in the scrubber tower was installed and evaluated for 8 months. [Evaluation points] ・ Even in the summer, when problems tend to occur, the odor in the factory is reduced to a value that does not cause problems. ・ 35% reduction in chemical cost compared to the disinfectant [sodium hypochlorite] used before ・ The adhesion _of minerals _and biofilm [propagation of germs] that had been seen before have been eliminated, _and maintenance costs have been reduced. ≪Advantages of chlorine dioxide≫ -It works as a powerful oxidizing agent _and efficiently decomposes odorous components "sulfide" _and "trimethylamine". The bactericidal effect lasts, so the inside of the tower is kept clean. ・ The effect does not decrease depending on the pH value. ・ No generation of trihalomethane
Unit Systems
- [Neutralizing equipment TPC continuous treatment type] Cement plant int the Kanto region (Japan)
- [Neutralizing equipment LPC batch treatment type] Food factory in the Kanto region (Japan)
- [Neutralizing equipment CPC carbon dioxide type]
- [Neutralizing equipment – three-stage neutralization] Chemical plant in the Kansai region (Japan)
- Organic tempering compound dissolving tank Human excreta treatment plant (Japan)
- [Dissolving equipment (medium-scale)]
- [Dissolving equipment (small-scale)]
- [Sterilization equipment for hospital waste] Hospital in the Shikoku region (Japan)
- Chlorine injection & monitoring equipment Waterworks
- [Measuring instruments for chlorine control of reservoir] Waterworks
- [Measuring instruments for weakly acidic hypochlorite water monitoring equipment] Beverage industry in the Tohoku region (Japan)
- Odor reduction by use of chlorine dioxide [Bello Zon] Seafood product industry in the Shikoku region (Japan)
- Chemical injection control “Feed-back control” for wastewater treatment [ProMix system] Electrical _and electronic industry in the Tohoku region (Japan)
- Chlorine dioxide generating equipment for Legionella removal [Bello Zon] Advanced medical facilities (Japan)
- Moving-layer type filtration equipment (small-scale) In the Shikoku region (Japan)
- Chemical Injection suitability for filter (basin) [ProMix system] Waterworks in the Shikoku region (Japan)
Head Office
1-12-11 Tagawakita, Yodogawa-ku,Osaka
532-0021
Overseas Business Department
TEL +81-6-6301-6460
FAX +81-6-6308-3022