Contact

Example

High-pressure plunger pumps

User
Power plant in the Kyushu region (Japan)
Product used
Sigma (plunger type)
Overview
Power plant
Category
Chemical Pump

Issues / requests

Pump for high pressure injection of boiler chemicals. A pump that can linearly change the discharge rate by receiving an external signal is required as the operating conditions change.

Tohkemy's proposal

We have proposed a Sigma plunger / control with a built-in inverter function. It has a function that the discharge amount is linearly proportional to the input signal (DC4-20mA). The maximum allowable discharge pressure of the pump is 32.0MPa, which is a model with sufficient margin. Since the power supply voltage is also a single-phase free power supply, it is easy to set regardless of the 50Hz / 60Hz region.

Chemical Pump

Head Office

1-12-11 Tagawakita, Yodogawa-ku,Osaka
532-0021

Overseas Business Department

TEL +81-6-6301-6460
FAX +81-6-6308-3022